Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 157.929
Filtrar
1.
J Strength Cond Res ; 38(5): 948-950, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38662886

RESUMEN

ABSTRACT: Peveler, WW, Schoffstall, J, Coots, J, Kilian, J, and Glauser, J. The effects of boxing glove design on thumb position when making a fist for striking. J Strength Cond Res 38(5): 948-950, 2024-It has been suggested that boxing glove design alters thumb position increasing the risk of injury. The purpose of this study was to determine the effects of boxing glove design on thumb joint angles when making a fist. Ten experienced fighters participated in this study. A DEXA scan was used to produce an x-ray image of thumb position for all conditions (no gloves and 10-oz boxing gloves). Mean values for dependent measures were compared using a paired-sample T test and an alpha of 0.05. The carpometacarpal (CMC) joint angle was significantly different between no glove (14.1 ± 6.54°) and boxing glove (34.2 ± 7.60°) at p ≤ 0.001. The metacarpophalangeal (MP) joint angle was significantly different between no glove (132.6 ± 12.74°) and boxing glove (149.40 ± 8.15°) at p ≤ 0.001. The IP joint angle was not significantly different between no glove (135.50 ± 19.12°) and boxing glove (144.40 ± 17.39°) at p = 0.269. The perpendicular distance from the second metacarpal of the hand to the center of the MP joint was significantly different between no glove (0.48 ± 0.54 cm) and boxing glove (1.84 ± 0.29 cm) at p ≤ 0.001. Use of a boxing glove resulted in abduction of the thumb away from the hand and increased CMC and MP joint angles that were significantly different in relation to making a fist without a glove. Information from this study may provide insight into the high rate of thumb injury and provide insight for future boxing glove design.


Asunto(s)
Diseño de Equipo , Pulgar , Humanos , Pulgar/fisiología , Adulto , Masculino , Boxeo/fisiología , Articulación Metacarpofalángica/fisiología , Articulaciones Carpometacarpianas , Adulto Joven , Guantes Protectores
2.
J Chromatogr A ; 1722: 464853, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38579611

RESUMEN

This study presents a methodology for designing effective insulator-based electrokinetic (iEK) systems for separating tertiary microparticle samples, which can be extended to more complex samples. First, 144 distinct iEK microchannel designs were built considering different shapes and arrangements of the insulating posts. Second, a mathematical model was developed with COMSOL software to predict the retention time of each particle type in the microchannel, this allowed identifying the best channel designs for two distinct types of separations: charge-based and sized-based. Third, the experimental charge-based and size-based separations of the tertiary microparticle mixtures were performed employing the improved designs identified with COMSOL modeling. The experimental results demonstrated successful separation in terms of separation resolution and good agreement with COMSOL predictions. The findings from this study show that the proposed method for device design, which combines mathematical modeling with varying post shape and post arrangement is an effective approach for identifying iEK systems capable of separating complex microparticle samples.


Asunto(s)
Diseño de Equipo , Técnicas Analíticas Microfluídicas/instrumentación , Modelos Teóricos , Tamaño de la Partícula
3.
Shanghai Kou Qiang Yi Xue ; 33(1): 54-58, 2024 Feb.
Artículo en Chino | MEDLINE | ID: mdl-38583025

RESUMEN

PURPOSE: To compare the forming ability of four kinds of nickel-titanium instrument preparation resin for simulated curved root canal. METHODS: A total of 40 single bend resin simulated root canals were randomly divided into 4 groups with 10 in each group. Four kinds of nickel-titanium instruments (ProTaper, HyFlex EDM, WaveOne Gold and Reciproc Blue) were used for root canal preparation, and divided into group A, group B, group C and group D. The preparation time of the four groups was compared, the root canal images before and after preparation were analyzed by computer image analysis software, and the changes of the preparation time, curvature and curvature radius of the four groups were recorded. With the root tip as the center of the circle, the radius of 1-10 mm was selected as concentric circle arcs. The detection points were overlapping root canal intersection points. The resin removal amount and center positioning force of the inner and outer walls of the root canal at different detection points were recorded. Statistical analysis was performed with SPSS 20.0 software package. RESULTS: The root canal preparation time in group A was significant longer than that in group B, C and D(P<0.05), but there was no significant difference in the curvature and curvature radius of the root canal among the four groups (P>0.05). The removal amount of resin from the root canal wall in group C was significant lower than that in group A, B and D (P<0.05) when the distance from the detection point to the apical foramina was 5, 6, 8, 9 and 10 mm, respectively. The removal amount of resin from the outer wall of the root canal in group C was significant lower than that in group A, B and D (P<0.05) when the distance from the detection point to the apical foramina was 5, 6, 7, 9 and 10 mm, respectively. The root tip offset of group A from the detection point to the apical hole of 1, 2, 3, 4, 6, 7, 8, 9 and 10 mm was significant greater than that of group B, C and D(P<0.05). CONCLUSIONS: Among the four instruments, ProTaper has the largest apical deviation, HyFlex EDM, WaveOne Gold and Reciproc Blue have better ability of root canal forming.


Asunto(s)
Cavidad Pulpar , Titanio , Níquel , Instrumentos Dentales , Preparación del Conducto Radicular/métodos , Diseño de Equipo
4.
Catheter Cardiovasc Interv ; 103(6): 972-981, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38606477

RESUMEN

BACKGROUND: Ethylene diamine tetra-acetic acid (EDTA) is a chelating agent used to dissolve calcium deposits but evidence in decalcifying atherosclerotic lesions is limited. AIMS: We assessed the feasibility and efficacy of EDTA delivered via porous balloon to target calcified lesions in cadaveric below-the-knee (BTK) arteries. METHODS: Using porcine carotid arteries, EDTA concentration was measured in the arterial wall and outside the artery at the 0-, 0.5-, 4-, and 24-h circulation after the injection through a porous balloon. In cadaver BTK samples, the proximal and distal anterior tibial artery (ATA) and distal posterior tibial artery (PTA) were studied. EDTA-2Na/H2O or EDTA-3Na/H2O were administrated using a porous balloon, then circulated for 6 h for EDTA-3Na/H2O and 24 h for EDTA-2Na/H2O and EDTA-3Na/H2O. Micro-CT imaging of the artery segments before and after the circulation and cross-sectional analyses were performed to evaluate calcium burden. RESULTS: In the porcine carotid study, EDTA was delivered through a porous balloon present in the arterial wall and was retained there for 24 h. In BTK arteries, cross-sectional analyses of micro-CT revealed a significant decrease in the calcium area in the distal ATA segment under 24-h circulation with EDTA-2Na/H2O and in the distal ATA segment under 24-h circulation with EDTA-3Na/H2O. The proximal ATA segment under 6-h circulation with EDTA-3Na/H2O showed no significant change in any parameters of calcium CONCLUSION: EDTA-3Na/H2O or EDTA-2Na/H2O with longer circulation times resulted in greater calcium reduction in atherosclerotic lesion. EDTA may have a potential therapeutic option for the treatment of atherosclerotic calcified lesions.


Asunto(s)
Angioplastia de Balón , Ácido Edético , Estudios de Factibilidad , Calcificación Vascular , Animales , Ácido Edético/farmacología , Angioplastia de Balón/instrumentación , Porosidad , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia , Cadáver , Arterias Tibiales/diagnóstico por imagen , Quelantes del Calcio/farmacología , Factores de Tiempo , Microtomografía por Rayos X , Humanos , Dispositivos de Acceso Vascular , Diseño de Equipo , Sus scrofa , Enfermedad Arterial Periférica/terapia , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/metabolismo , Placa Aterosclerótica , Porcinos
5.
J Chromatogr A ; 1722: 464904, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38626539

RESUMEN

A continuously regenerated cationic impurity removal device (CR-CRD) has been fabricated and applied for ion chromatography (IC). The removal of cationic impurities is realized by electrodialytically replacing the cationic impurities with hydronium ions. The device is configured in a sandwich structure and the central eluent channel is respectively isolated from both electrodes by stacked cation exchange membranes and a bipolar membrane (BPM) plus stacked anion exchange membranes. The eluent channel is packed with cation exchange resins in hydronium form and their continuous regeneration can be achieved by electrodialysis. A desirable feature of the device is gas-free, and no degasser is required. It showed sufficient ability to remove cationic impurities, as indicated by > 99.9 % removal of 10 mL of 1 mM LiOH solution injected (∼10 µmol) or continuous removal of 1 mM LiOH solution at the flow rate of 1 mL/min (1 µmol/min). A useful application was for sample pretreatment in nuclear power industry, by eliminating strong matrix interference of the sample containing LiOH (1 mM) and boric acid (2000 mg/L) with trace anion analysis.


Asunto(s)
Cationes , Cromatografía por Intercambio Iónico/métodos , Cromatografía por Intercambio Iónico/instrumentación , Cationes/química , Membranas Artificiales , Resinas de Intercambio de Catión/química , Diseño de Equipo
6.
Biomed Phys Eng Express ; 10(3)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38626737

RESUMEN

A novel fiber optic biosensor was purposed for a new approach to monitor amyloid beta protein fragment 1-42 (Aß42) for Alzheimer's Disease (AD) early detection. The sensor was fabricated by etching a part of fiber from single mode fiber loop in pure hydrofluoric acid solution and utilized as a Local Optical Refractometer (LOR) to monitor the change Aß42 concentration in Artificial Cerebrospinal Fluid (ACSF). The Fiber Loop Ringdown Spectroscopy (FLRDS) technique is an ultra-sensitive measurement technique with low-cost, high sensitivity, real-time measurement, continuous measurement and portability features that was utilized with a fiber optic sensor for the first time for the detection of a biological signature in an ACSF environment. Here, the measurement is based on the total optical loss detection when specially fabricated sensor heads were immersed into ACSF solutions with and without different concentrations of Aß42 biomarkers since the bulk refractive index change was performed. Baseline stability and the reference ring down times of the sensor head were measured in the air as 0.87% and 441.6µs ± 3.9µs, respectively. Afterward, the total optical loss of the system was measured when the sensor head was immersed in deionized water, ACSF solution, and ACSF solutions with Aß42 in different concentrations. The lowest Aß42 concentration of 2 ppm was detected by LOR. Results showed that LOR fabricated by single-mode fibers for FLRDS system design are promising candidates to be utilized as fiber optic biosensors after sensor head modification and have a high potential for early detection applications of not only AD but possibly also several fatal diseases such as diabetes and cancer.


Asunto(s)
Enfermedad de Alzheimer , Péptidos beta-Amiloides , Técnicas Biosensibles , Diagnóstico Precoz , Tecnología de Fibra Óptica , Fragmentos de Péptidos , Análisis Espectral , Enfermedad de Alzheimer/diagnóstico , Péptidos beta-Amiloides/análisis , Humanos , Tecnología de Fibra Óptica/métodos , Fragmentos de Péptidos/análisis , Técnicas Biosensibles/métodos , Análisis Espectral/métodos , Fibras Ópticas , Biomarcadores/análisis , Refractometría , Diseño de Equipo
7.
J Biomed Opt ; 29(4): 046008, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38659998

RESUMEN

Significance: Optical imaging is a non-invasive imaging technology that utilizes near-infrared light, allows for the image reconstruction of optical properties like diffuse and absorption coefficients within the tissue. A recent trend is to use signal processing techniques or new light sources and expanding its application. Aim: We aim to develop the reflective optical imaging using the chaotic correlation technology with chaotic laser and optimize the quality and spatial resolution of reflective optical imaging. Approach: Scattering medium was measured using reflective configuration in different inhomogeneous regions to evaluate the performance of the imaging system. The accuracy of the recovered optical properties was investigated. The reconstruction errors of absorption coefficients and geometric centers were analyzed, and the feature metrics of the reconstructed images were evaluated. Results: We showed how chaotic correlation technology can be utilized for information extraction and image reconstruction. This means that a higher signal-to-noise ratio and image reconstruction of inhomogeneous phantoms under different scenarios successfully were achieved. Conclusions: This work highlights that the peak values of correlation of chaotic exhibit smaller reconstruction error and better reconstruction performance in optical imaging compared with reflective optical imaging with the continuous wave laser.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Rayos Láser , Imagen Óptica , Fantasmas de Imagen , Dispersión de Radiación , Imagen Óptica/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Relación Señal-Ruido , Dinámicas no Lineales , Algoritmos , Diseño de Equipo
8.
Biosensors (Basel) ; 14(4)2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38667197

RESUMEN

Microfluidic impedance cytometry (MIC) has emerged as a popular technique for single-cell analysis. Traditional MIC electrode designs consist of a pair of (or three) working electrodes, and their detection performance needs further improvements for microorganisms. In this study, we designed an 8-electrode MIC device in which the center pair was defined as the working electrode, and the connection status of bypass electrodes could be changed. This allowed us to compare the performance of layouts with no bypasses and those with floating or grounding electrodes by simulation and experiment. The results of detecting Φ 5 µm beads revealed that both the grounding and the floating electrode outperformed the no bypass electrode, and the grounding electrode demonstrated the best signal-to-noise ratio (SNR), coefficient of variation (CV), and detection sensitivity. Furthermore, the effects of different bypass grounding areas (numbers of grounding electrodes) were investigated. Finally, particles passing at high horizontal positions can be detected, and Φ 1 µm beads can be measured in a wide channel (150 µm) using a fully grounding electrode, with the sensitivity of bead volume detection reaching 0.00097%. This provides a general MIC electrode optimization technology for detecting smaller particles, even macromolecular proteins, viruses, and exosomes in the future.


Asunto(s)
Impedancia Eléctrica , Electrodos , Relación Señal-Ruido , Microfluídica , Técnicas Biosensibles , Diseño de Equipo , Citometría de Flujo , Técnicas Analíticas Microfluídicas
9.
Proc Natl Acad Sci U S A ; 121(16): e2314359121, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38557166

RESUMEN

Suction is a highly evolved biological adhesion strategy for soft-body organisms to achieve strong grasping on various objects. Biological suckers can adaptively attach to dry complex surfaces such as rocks and shells, which are extremely challenging for current artificial suction cups. Although the adaptive suction of biological suckers is believed to be the result of their soft body's mechanical deformation, some studies imply that in-sucker mucus secretion may be another critical factor in helping attach to complex surfaces, thanks to its high viscosity. Inspired by the combined action of biological suckers' soft bodies and mucus secretion, we propose a multiscale suction mechanism which successfully achieves strong adaptive suction on dry complex surfaces which are both highly curved and rough, such as a stone. The proposed multiscale suction mechanism is an organic combination of mechanical conformation and regulated water seal. Multilayer soft materials first generate a rough mechanical conformation to the substrate, reducing leaking apertures to micrometres (~10 µm). The remaining micron-sized apertures are then sealed by regulated water secretion from an artificial fluidic system based on the physical model, thereby the suction cup achieves long suction longevity on complex surfaces but minimal overflow. We discuss its physical principles and demonstrate its practical application as a robotic gripper on a wide range of complex dry surfaces. We believe the presented multiscale adaptive suction mechanism is a powerful unique adaptive suction strategy which may be instrumental in the development of versatile soft adhesion.


Asunto(s)
Robótica , Agua , Succión , Diseño de Equipo
10.
Opt Lett ; 49(7): 1741-1744, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38560851

RESUMEN

Speckle-correlation optical scattering imaging (SCOSI) has shown the potential for non-invasive biomedical diagnostic applications, which directly utilizes the scattering patterns to reconstruct the deep and non-line-of-sight objects. However, the course of the translation of this technique to preclinical biomedical imaging applications has been postponed by the following two facts: 1) the field of view of SCOSI was significantly limited by the optical memory effect, and 2) the molecular-tagged functional imaging of the biological tissues remains largely unexplored. In this work, a proof-of-concept design of the first-generation widefield functional SCOSI (WF-SCOSI) system was presented for simultaneously achieving mesoscopic mapping of fluid morphology and flow rate, which was realized by implementing the concepts of scanning synthesis and fluorescence scattering flowmetry. The ex vivo imaging results of the fluorescence-labeled large-scale blood vessel network phantom underneath the strong scatters demonstrated the effectiveness of WF-SCOSI toward non-invasive hemodynamic imaging applications.


Asunto(s)
Diagnóstico por Imagen , Hemodinámica , Fantasmas de Imagen , Reología , Diseño de Equipo , Imagen Óptica/métodos
11.
PLoS One ; 19(4): e0299896, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38568900

RESUMEN

The objective was to evaluate the effect of glide path and coronal flaring on the dentin volume removal and percentage of touched walls in curved canals using two heat-treated rotary files. The mesiobuccal canal of forty-eight, randomly selected, extracted mandibular molars was divided into two groups of 24 each, according to the type of instrument used (RACE EVO and EdgeSequel rotary files). Each group was further divided into three subgroups; Group (A): Control using one file shaped to 04/30, Group (B) with a glide path (EdgeGlidePath (EGP)), and Group (C): with a glide path and coronal flaring (EGP and EdgeTaper Platinum (ETP) SX file respectively). The root canals were then instrumented using the assigned instruments. The assessment was carried out using micro-CT. The comparison of the mean values of the tested groups about dentin volume removal and percentage of untouched walls did not reach statistical significance (p<0.05). Glide path and coronal flaring had an insignificant effect on the dentin volume removal and percentage of untouched walls in curved canals.


Asunto(s)
Calor , Níquel , Preparación del Conducto Radicular , Microtomografía por Rayos X/métodos , Preparación del Conducto Radicular/métodos , Aleaciones , Titanio , Cavidad Pulpar/diagnóstico por imagen , Cavidad Pulpar/cirugía , Diseño de Equipo
12.
Sci Robot ; 9(89): eadp1956, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38657089

RESUMEN

Advances in engineering enable wheeled-legged hybrid locomotion, an achievement not feasible in biological systems.


Asunto(s)
Biomimética , Locomoción , Robótica , Robótica/instrumentación , Humanos , Biomimética/instrumentación , Locomoción/fisiología , Diseño de Equipo , Animales
13.
Sci Robot ; 9(89): eadi9754, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38657092

RESUMEN

Animals are much better at running than robots. The difference in performance arises in the important dimensions of agility, range, and robustness. To understand the underlying causes for this performance gap, we compare natural and artificial technologies in the five subsystems critical for running: power, frame, actuation, sensing, and control. With few exceptions, engineering technologies meet or exceed the performance of their biological counterparts. We conclude that biology's advantage over engineering arises from better integration of subsystems, and we identify four fundamental obstacles that roboticists must overcome. Toward this goal, we highlight promising research directions that have outsized potential to help future running robots achieve animal-level performance.


Asunto(s)
Robótica , Robótica/instrumentación , Animales , Diseño de Equipo , Carrera/fisiología , Fenómenos Biomecánicos , Humanos
14.
Sci Robot ; 9(89): eadp8528, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38657090

RESUMEN

A smart suction cup uses haptics to supplement vision for exploration of objects in a grasping task.


Asunto(s)
Diseño de Equipo , Fuerza de la Mano , Robótica , Humanos , Fuerza de la Mano/fisiología , Robótica/instrumentación , Tacto , Fenómenos Biomecánicos , Mano/fisiología
15.
J Neuroeng Rehabil ; 21(1): 62, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38658969

RESUMEN

BACKGROUND: Stroke remains a major cause of long-term adult disability in the United States, necessitating the need for effective rehabilitation strategies for post-stroke gait impairments. Despite advancements in post-stroke care, existing rehabilitation often falls short, prompting the development of devices like robots and exoskeletons. However, these technologies often lack crucial input from end-users, such as clinicians, patients, and caregivers, hindering their clinical utility. Employing a human-centered design approach can enhance the design process and address user-specific needs. OBJECTIVE: To establish a proof-of-concept of the human-centered design approach by refining the NewGait® exosuit device for post-stroke gait rehabilitation. METHODS: Using iterative design sprints, the research focused on understanding the perspectives of clinicians, stroke survivors, and caregivers. Two design sprints were conducted, including empathy interviews at the beginning of the design sprint to integrate end-users' insights. After each design sprint, the NewGait device underwent refinements based on emerging issues and recommendations. The final prototype underwent mechanical testing for durability, biomechanical simulation testing for clinical feasibility, and a system usability evaluation, where the new stroke-specific NewGait device was compared with the original NewGait device and a commercial product, Theratogs®. RESULTS: Affinity mapping from the design sprints identified crucial categories for stakeholder adoption, including fit for females, ease of donning and doffing, and usability during barefoot walking. To address these issues, a system redesign was implemented within weeks, incorporating features like a loop-backed neoprene, a novel closure mechanism for the shoulder harness, and a hook-and-loop design for the waist belt. Additional improvements included reconstructing anchors with rigid hook materials and replacing latex elastic bands with non-latex silicone-based bands for enhanced durability. Further, changes to the dorsiflexion anchor were made to allow for barefoot walking. Mechanical testing revealed a remarkable 10-fold increase in durability, enduring 500,000 cycles without notable degradation. Biomechanical simulation established the modularity of the NewGait device and indicated that it could be configured to assist or resist different muscles during walking. Usability testing indicated superior performance of the stroke-specific NewGait device, scoring 84.3 on the system usability scale compared to 62.7 for the original NewGait device and 46.9 for Theratogs. CONCLUSION: This study successfully establishes the proof-of-concept for a human-centered design approach using design sprints to rapidly develop a stroke-specific gait rehabilitation system. Future research should focus on evaluating the clinical efficacy and effectiveness of the NewGait device for post-stroke rehabilitation.


Asunto(s)
Diseño de Equipo , Dispositivo Exoesqueleto , Trastornos Neurológicos de la Marcha , Rehabilitación de Accidente Cerebrovascular , Humanos , Rehabilitación de Accidente Cerebrovascular/instrumentación , Rehabilitación de Accidente Cerebrovascular/métodos , Trastornos Neurológicos de la Marcha/rehabilitación , Trastornos Neurológicos de la Marcha/etiología , Diseño Centrado en el Usuario , Femenino , Fenómenos Biomecánicos , Masculino , Persona de Mediana Edad , Robótica/instrumentación , Cuidadores
17.
Biosens Bioelectron ; 256: 116277, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38613934

RESUMEN

The field of biosensing would significantly benefit from a disruptive technology enabling flexible manufacturing of uniform electrodes. Inkjet printing holds promise for this, although realizing full electrode manufacturing with this technology remains challenging. We introduce a nitrogen-doped carboxylated graphene ink (NGA-ink) compatible with commercially available printing technologies. The water-based and additive-free NGA-ink was utilized to produce fully inkjet-printed electrodes (IPEs), which demonstrated successful electrochemical detection of the important neurotransmitter dopamine. The cost-effectiveness of NGA-ink combined with a total cost per electrode of $0.10 renders it a practical solution for customized electrode manufacturing. Furthermore, the high carboxyl group content of NGA-ink (13 wt%) presents opportunities for biomolecule immobilization, paving the way for the development of advanced state-of-the-art biosensors. This study highlights the potential of NGA inkjet-printed electrodes in revolutionizing sensor technology, offering an affordable, scalable alternative to conventional electrochemical systems.


Asunto(s)
Técnicas Biosensibles , Dopamina , Técnicas Electroquímicas , Grafito , Tinta , Impresión , Técnicas Biosensibles/instrumentación , Grafito/química , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Dopamina/análisis , Electrodos , Diseño de Equipo , Nitrógeno/química , Humanos
18.
Biosens Bioelectron ; 256: 116260, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38613935

RESUMEN

Various bioelectronic noses have been recently developed for mimicking human olfactory systems. However, achieving direct monitoring of gas-phase molecules remains a challenge for the development of bioelectronic noses due to the instability of receptor and the limitations of its surrounding microenvironment. Here, we report a MXene/hydrogel-based bioelectronic nose for the sensitive detection of liquid and gaseous hexanal, a signature odorant from spoiled food. In this study, a conducting MXene/hydrogel structure was formed on a sensor via physical adsorption. Then, canine olfactory receptor 5269-embedded nanodiscs (cfOR5269NDs) which could selectively recognize hexanal molecules were embedded in the three-dimensional (3D) MXene/hydrogel structures using glutaraldehyde as a linker. Our MXene/hydrogel-based bioelectronic nose exhibited a high selectivity and sensitivity for monitoring hexanal in both liquid and gas phases. The bioelectronic noses could sensitively detect liquid and gaseous hexanal down to 10-18 M and 6.9 ppm, and they had wide detection ranges of 10-18 - 10-6 M and 6.9-32.9 ppm, respectively. Moreover, our bioelectronic nose allowed us to monitor hexanal levels in fish and milk. In this respect, our MXene/hydrogel-based bioelectronic nose could be a practical strategy for versatile applications such as food spoilage assessments in both liquid and gaseous systems.


Asunto(s)
Técnicas Biosensibles , Nariz Electrónica , Técnicas Biosensibles/métodos , Animales , Gases/química , Gases/análisis , Aldehídos/química , Análisis de los Alimentos/instrumentación , Análisis de los Alimentos/métodos , Perros , Receptores Odorantes/química , Humanos , Leche/microbiología , Leche/química , Diseño de Equipo , Odorantes/análisis
19.
Biosens Bioelectron ; 256: 116280, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38603840

RESUMEN

Monitoring biomarkers in human interstitial fluids (ISF) using microneedle sensors has been extensively studied. However, most of the previous studies were limited to simple in vitro demonstrations and lacked system integration and analytical performance. Here we report a miniaturized, high-precision, fully integrated wearable electrochemical microneedle sensing device that works with a customized smartphone application to wirelessly and in real-time monitor glucose in human ISF. A microneedle array fabrication method is proposed which enables multiple individually addressable, regionally separated sensing electrodes on a single microneedle system. As a demonstration, a glucose sensor and a differential sensor are integrated in a single sensing patch. The differential sensing electrodes can eliminate common-mode interference signals, thus significantly improving the detection accuracy. The basic mechanism of microneedle penetration into the skin was analyzed using the finite element method (FEM). By optimizing the structure of the microneedle, the puncture efficiency was improved while the puncture force was reduced. The electrochemical properties, biocompatibility, and system stability of the microneedle sensing device were characterized before human application. The test results were closely correlated with the gold standard (blood). The platform can be used not only for glucose detection, but also for various ISF biomarkers, and it expands the potential of microneedle technology in wearable sensing.


Asunto(s)
Técnicas Biosensibles , Diseño de Equipo , Líquido Extracelular , Glucosa , Agujas , Dispositivos Electrónicos Vestibles , Humanos , Líquido Extracelular/química , Técnicas Biosensibles/instrumentación , Glucosa/análisis , Teléfono Inteligente , Automonitorización de la Glucosa Sanguínea/instrumentación , 60431
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...